Sign In | Join Free | My burrillandco.com
Home > Low Voltage Isolator >

GW4 40.5KV Substation Type Low Voltage Disconnector With Manual Operated Mechanism

Hangzhou Yongde Electric Appliances Co.,Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap GW4 40.5KV Substation Type Low Voltage Disconnector With Manual Operated Mechanism from wholesalers
     
    Buy cheap GW4 40.5KV Substation Type Low Voltage Disconnector With Manual Operated Mechanism from wholesalers
    • Buy cheap GW4 40.5KV Substation Type Low Voltage Disconnector With Manual Operated Mechanism from wholesalers
    • Buy cheap GW4 40.5KV Substation Type Low Voltage Disconnector With Manual Operated Mechanism from wholesalers

    GW4 40.5KV Substation Type Low Voltage Disconnector With Manual Operated Mechanism

    Ask Lasest Price
    Brand Name : YONGDE
    Model Number : GW4-40.5
    Certification : ISO9001
    Price : negotiation
    Payment Terms : T/T or western Union or L/C or PayPal, MoneyGram, D/P, D/A
    Supply Ability : 1,000pcs per month
    Delivery Time : 21days per container
    • Product Details
    • Company Profile

    GW4 40.5KV Substation Type Low Voltage Disconnector With Manual Operated Mechanism

    GW4 40.5KV Substation Type Low Voltage Disconnecting Switch Isolator with Manual Operated Mechanism


    GW4 Isolator Switch Description:


    This type disconnector is a kind of HV outdoor electric equipments used in three-phase AC 50Hz electrical system . It is used for swithing-on/off the HV circuit when there is no load in the circuit in order to charge or transfer the circuit and also dissconnect the current with the bus bar , breaker or any other HV electrical equipments when overhauling the circuitry .


    Specifications:


    NoItemsTechnical parameter
    1Rated Voltage kV40.5121820
    2Nominal system voltage kV35101520
    3Rated current A630;1250;1600;2000;2500;3150;4000
    4Rated Short Time withstand current and Time kA/s25~50/4
    5Rated Peak withstand current kA63~125
    61min power frequency withstand voltage (effective value) kVTo earth95/85424565
    To phase95/85
    Across Isolating DS118535579
    7Lightning Impulse wishstand voltage(peak value) KVTo earth18575105125
    To phase185
    Across Isolating DS21085120145
    8Rated mechanical terminal load NLevel of lateral load500500500500
    Level of vertical load250250250250
    Vertical500500500500
    9The min distance of insulation against ground mm400
    10Max Man Operative Moment N. m200
    11Motor Drive operating mechanism control voltage VAC220,380; DC110,220
    12Motor Drive operating mechanism motor voltage VAC220,380; DC110,220